Product Introduction

1. Product descriptions: temperature/water-holdup/flow logger is a kind of instrument used to measure the well temperature, water holdup, and flow by combining three types of sensors and the electronic part into a swage nipple. The electronic circuit functions as a signal handler of the three sensors. The lower end of the instrument is connected to the mechanical body of the flowmeter to carry out measurement. The mechanical body can be selected to meet continuous flow or full borehole flow. The device is simple in structure and easy to operate. 2. Application range: water holdup flow analysis, fluid compositions, and temperature measurement to determine the leak sources and cross flow, and quantitative flow analysis.

 

Technical Parameters:

1. Temperature: 175℃. 2. Pressure: 100 MPa. 3. Cable: single core. 4. Operating voltage: 18 V (WSTbus). 5. Operating current: 45 mA±3 mA. 6. Water holding ratio measurement range: 0-45%. 7. Water holding ratio accuracy: 0.01. 8. Temperature measurement range: 0-175℃. 9. Temperature resolution: 0.01℃. 10. Temperature accuracy: ± 2℃. 11. Response time: less than 0.5 s. 12. Flow output: 10 pulse/revolution. 13: Logging speed: more than 400 m/h.

After-sales Service:
On-site installation with technological guidance, regular equipment inspection, and training.
We have marketing teams in regions where key accounts located, also we prepare special stock area in the local warehouses for key accounts, to timely provide necessary parts and consumable products. Problem solving & Complaints settlement
After-sales Procedures:

(Customer Center)Apply
for after-sale service

Solutions released
within 48h

(Customer Center)Apply
Satisfaction survey

Respond within 24h

Execution of the solution

Specifications
Specifications HTF02
Model HTF02
Temperature (℃) 175
Pressure (MPa) 100
Cable Single core cable
Operating voltage (V) 18
Operating current (mA) 45±3
Water holding ratio measurement range 0-45%
Water holding ratio accuracy 0.01
Temperature measuring range (℃) 0 - 175
Temperature resolution (℃) 0.01
Temperature accuracy (℃) ± 2
Response time (S) < 0.5
Flow output (pulse/revolution) 10
Logging speed (m/h) > 400
Functional use
Flow Logger
Accomplished Quality Control System:
To provide with all-around service of quality control, quality guarantee, and authority certification.
After-sales Service:
On-site installation with technological guidance, regular equipment inspection, and training.
We have marketing teams in regions where key accounts located, also we prepare special stock area in the local warehouses for key accounts, to timely provide necessary parts and consumable products. Problem solving & Complaints settlement